蚕庄金矿上庄矿区充填系统改造及应用

  • 作者:
  • 张阳阳|刘哲君|刘同喜|李元龙|刘俊坤
  • 作者单位:
  • 招金矿业股份有限公司蚕庄金矿|招金矿业股份有限公司蚕庄金矿|招金矿业股份有限公司蚕庄金矿|招金矿业股份有限公司蚕庄金矿|招金矿业股份有限公司蚕庄金矿
  • 基金项目:

  • isnull
  • 详细信息:

  • 作者简介:
  • 张阳阳(1991—),男,山东潍坊人,助理工程师,从事金属矿山采矿技术研究工作;山东省招远市蚕庄镇西上庄村,招金矿业股份有限公司蚕庄金矿,265400;E-mail:768579012@qq.com
  • 通讯作者:
  • isnull
  • 此文档没有上传!

Renovation of filling system in Shangzhuang Mining District of Canzhuang Gold Mine and its application

  • English Author:
  • Canzhuang Gold Mine,Zhaojin Mining Industry Co.,Ltd.|Canzhuang Gold Mine,Zhaojin Mining Industry Co.,Ltd.|Canzhuang Gold Mine,Zhaojin Mining Industry Co.,Ltd.|Canzhuang Gold Mine,Zhaojin Mining Industry Co.,Ltd.|Canzhuang Gold Mine,Zhaojin Mining Industry Co.,Ltd.
  • Unit:
  • 摘要
  • 在线预览
  • 参考文献

摘要:

针对蚕庄金矿上庄矿区存在的采充不平衡,以及井下滤水增加、胶结料流失严重和充填体强度达不到要求等问题,分析了充填系统存在的问题及原因,并对其进行改造。主要的改造措施有:重新设计地表充填站,改卧式砂仓为立式砂仓,试验选择胶结充填材料,对充填设备进行选型。工业应用表明:改造后的充填系统实现了连续充填,每班充填能力达150 m3/h,且提升了充填料浆浓度,缩短了近一半的充填滤水时间,改造效果良好,可供同类型矿山参考借鉴。

关键词:

上向分层分级尾砂胶结充填采矿法;充填系统;采充平衡;充填滤水;充填站;设备选型

Abstract:

There are problems such as imbalance between mining and filling,increasing underground drainage water,cemented materials loss,unqualified filling body strength in the Shangzhuang Mining District of Canzhuang Gold Mine.The paper analyzed the problems and their causes in filling system and renovated it:the surface filling stations were redesigned,replacing the horizontal sand cabin by vertical one,selected cemented filling materials and the filling equipment.Industrial application shows that the renovated filling system realized continuous filling with filling capacity reaching 150 m3/h per shift.What’s more,the filling slurry concentration was improved and the drainage time is shortened by nearly a half.The renovation outcome is good and the study can be used as reference by similar mines.

Keywords:

upward slicing and graded tailings cemented filling mining method;filling system;balance of mining and filling;filling drainage water;filling station;equipment selection