Chinese core journals in science and technology

Chemical Abstracts Service (CAS) database

EBSCO Academic Database in the United States

Japan Science and Technology Agency Database (JST)

Journal Guide

Home   >   Journal Articles

Nickel content determination in coarse gold

  • English Author:
  • Changchun Gold Research Institute Co.,Ltd.&National Quality Supervision and Inspection Center for Gold and Silver Products(Changchun)|Changchun Gold Research Institute Co.,Ltd.&National Quality Supervision and Inspection Center for Gold and Silver Products(Changchun)|Changchun Gold Research Institute Co.,Ltd.&National Quality Supervision and Inspection Center for Gold and Silver Products(Changchun)|Changchun Gold Research Institute Co.,Ltd.&National Quality Supervision and Inspection Center for Gold and Silver Products(Changchun)|Changchun Gold Research Institute Co.,Ltd.&National Quality Supervision and Inspection Center for Gold and Silver Products(Changchun)
  • Unit:
  • This document has not been uploaded!
  • Abstract
  • Online Preview
  • References

Abstract:

The study established volumetric method to determine nickel content in coarse gold.Through condition test,the minimum sample weight,the dosage of dimethylglyoxime to precipitate nickel and the manner of precipitate dissolution were determined.The RSD of the determination results is <2.00 %.The recovery rate of reference material is 98.05 %-100.38 %.The accuracy and precision are good.The method is suitable for batch determination of nickel content in coarse gold.

Keywords:

coarse gold;nickel;inverse titration;precipitation separation;dimethylglyoxime