高级检索

碘量法测定铜精矿中的铜

Determination of copper in copper concentrates by iodometry

  • 摘要: 国家标准方法中短碘量法测定铜精矿中的铜操作简单,对设备要求不高,应用广泛。实验对测定过程中的细节操作进行了考察,包括电炉温度、滴定时间、摇动方式、试剂加入时间等。在实验确定的最佳条件下,该方法测定结果的平均偏差为0.002 %,相对标准偏差为0.166 %,准确度和精密度良好。

     

    Abstract: The short iodometry method in the national standards is easy to conduct and has no serious requirement for equipment and is widely applied when it is used to determine copper in copper concentrates.The details,including electric furnace temperature,titration time,shaking manner,agent addition time in the test are investigated.Under the optimal conditions determined by the test,the error of the determination results of the method is 0.002 % and the RSD is 0.166 %,the accuracy and precision are good.

     

/

返回文章
返回